The new submersible pumps, available in 12V and 24V, ensure quick installation, easy maintenance and reliable operation, even under demanding onboard operating conditions. The motor–impeller bayonet coupling design allows the motor to be replaced without disconnecting hoses or removing the pump body from the bilge, significantly reducing service time and simplifying maintenance operations. The multifunction hose fittings, compatible with two hose diameters, provides installation flexibility for both new systems and retrofit applications. The integrated check valve prevents water backflow and ensures complete bilge drainage, improving overall system efficiency and reducing unwanted pump activations. ISO 8849 and ISO 8846 certified.

Technical details

Part n. (12V / 24V)

16012112 / 16012113

Product name

UP1001

Voltage

12V DC / 24V DC

Max flow rate

63 l/min (16.6 gpm)

Max pressure

0.4 bar (5.8 psi)

Lift

4 m

Max amperage

4 A (12V) / 2.5 A (24V)

Fuse

7.5 A (12V) / 5 A (24V)

Motor power

48 W (12V) / 60 W (24V)

IP protection

IP67

Wire

0.75 mm² (18 AWG)

Hose

25 mm - 29 mm (two diameters)

Seal / O-ring

NBR / NBR

Features

Integrated check valve, bayonet motor, easy maintenance

Weight

0.5 kg (1.1 lb)

Dimensions L x W x H

135 x 70 x 118 mm (5 3/8" x 2 3/4" x 4 5/8")

Standards

ISO 8849, ISO 8846

Fluids

Allowed:

  • Water (fresh water and salt water), up to 43 °C

Not allowed:

  • Petrol (gasoline)

  • Solvents

  • Flammable liquids with flashpoint below 38 °C

  • Liquids with viscosity above 20 cSt

  • Corrosive chemical products

Installation notes

  • Install a correctly rated fuse (7.5 A on 12V, 5 A on 24V). Installing the fuse is compulsory.

  • Brown (+) wire to the positive battery terminal, black (-) wire to the negative terminal.

  • Make the electrical installation in a dry place to avoid contact with water.

  • Use correct bilge pump hose, keep the hose run as short and steep as possible to avoid air locks, and fix hoses with stainless steel clamps.

  • Mounting: lift the power module out of the strainer, fix the strainer with stainless steel screws, then insert the power module back onto the strainer.